西門子調速器6RA7095上電報警F007解決方法
西門(men)子(zi)直(zhi)流(liu)(liu)調(diao)速(su)器故(gu)(gu)障(zhang);西門(men)子(zi)6RA70調(diao)速(su)器無(wu)法啟動(dong)維(wei)(wei)(wei)修(xiu)(xiu)(xiu),三相(xiang)不(bu)(bu)(bu)平衡維(wei)(wei)(wei)修(xiu)(xiu)(xiu),無(wu)輸出維(wei)(wei)(wei)修(xiu)(xiu)(xiu),開機(ji)(ji)(ji)無(wu)顯示維(wei)(wei)(wei)修(xiu)(xiu)(xiu),啟動(dong)無(wu)勵磁(ci)電壓維(wei)(wei)(wei)修(xiu)(xiu)(xiu),上電跳閘維(wei)(wei)(wei)修(xiu)(xiu)(xiu),通電燒可控硅維(wei)(wei)(wei)修(xiu)(xiu)(xiu),運(yun)行(xing)模塊炸維(wei)(wei)(wei)修(xiu)(xiu)(xiu),速(su)度不(bu)(bu)(bu)可控維(wei)(wei)(wei)修(xiu)(xiu)(xiu),主板故(gu)(gu)障(zhang)維(wei)(wei)(wei)修(xiu)(xiu)(xiu),控制(zhi)板壞維(wei)(wei)(wei)修(xiu)(xiu)(xiu),轉速(su)不(bu)(bu)(bu)正(zheng)常(chang)維(wei)(wei)(wei)修(xiu)(xiu)(xiu),開不(bu)(bu)(bu)了(le)機(ji)(ji)(ji)維(wei)(wei)(wei)修(xiu)(xiu)(xiu),過(guo)流(liu)(liu),過(guo)壓,過(guo)熱,速(su)度不(bu)(bu)(bu)穩維(wei)(wei)(wei)修(xiu)(xiu)(xiu), 電機(ji)(ji)(ji)抖動(dong),低(di)速(su)不(bu)(bu)(bu)穩,高(gao)速(su)飛車,電機(ji)(ji)(ji)不(bu)(bu)(bu)轉等故(gu)(gu)障(zhang)維(wei)(wei)(wei)修(xiu)(xiu)(xiu)。
主(zhu)(zhu)裝置優化:把聯軸器(qi)(qi)拆開,然(ran)后在(zai)從裝置設置p171=p172=0,然(ran)后在(zai)主(zhu)(zhu)裝置上執行p051=25電流調(diao)節(jie)器(qi)(qi)及其預控優化,p051=26速度調(diao)節(jie)器(qi)(qi)優化,p051=27弱(ruo)磁調(diao)節(jie)器(qi)(qi)優化,后再把從裝置p171,p172參(can)數恢復原值,主(zhu)(zhu)裝置優化完畢。
從裝置(zhi)優化(hua):把主裝置(zhi)參數p171=p172=0,從裝置(zhi)p601.1由(you)koo15改為(wei)(wei)k0141,然(ran)后(hou)(hou)在從裝置(zhi)上執(zhi)行p051=25電(dian)流調(diao)(diao)節器及其(qi)預(yu)控優化(hua),p051=27弱(ruo)磁調(diao)(diao)節器優化(hua),然(ran)后(hou)(hou)把主裝置(zhi)參數p171,p172恢(hui)復原值(zhi),把從裝置(zhi)p601.1由(you)k0141改為(wei)(wei)koo15優化(hua)完畢。
西門子調速器6RA7095上電報警F007解決方法
后再把(ba)聯(lian)軸(zhou)器連(lian)接上,之(zhi)后再一起進行優化(hua)(hua),在主(zhu)裝置上執行p051=26速度調(diao)節(jie)器優化(hua)(hua)(注意(yi)兩立輥(gun)必須聯(lian)軸(zhou),否則(ze)會出現優化(hua)(hua)效果不良,主(zhu)從(cong)裝置電流(liu)偏差過大(da)影響正常使用(yong))主(zhu)從(cong)裝置優化(hua)(hua)完(wan)畢。
備(bei)注:p171(轉(zhuan)矩方向的(de)1系統(tong)電(dian)(dian)流限幅(fu)),p172(轉(zhuan)矩方向11的(de)系統(tong)電(dian)(dian)流限幅(fu))。